Sales: 888-864-4537
Fax: 203- 857-2201
Email: info@wejit.com
|

|

Installation Instructions
- Drill hole of recommended diameter (slightly deeper than length of shield).
- Clean the hole using compressed air and a nylon brush.
- Install shield flush with surface of hole threaded side down. Double shield should be flush to slightly below masonry.
- Place fixture. Insert machine bolt through fixture into shield and tighten.
- Single: To determine length of bolt: thickness of fixture plus length of shield, equals length of bolt
Double: A deep setting increases holding power of masonry. If desired, place a pipe sleeve between shield and
fixture being attached.
NOTE: Always wear safety glasses. Follow the drill manufacturer's safety instructions. Use only solid carbide-tipped drill bits meeting ANSI B212.15 diameter standards.
|

©2002-2012 The Mechanical Plastics Corp., all rights reserved. ® &™ denote trademarks owned by or licensed to Mechanical Plastics Corp., its affiliates, or partners. |