ALLIGATOR® Solid-Wall Anchors
General Info Installation Application/Materials Technical Info

DOWNLOAD TECHNICAL BULLETIN

If you need technical information about the TOGGLER® BRAND ALLIGATOR® solid-wall anchors, there is a complete Technical Bulletin dedicated just to this anchor line.
Please consult this bulletin for full results of tests and safety factors that should be applied when evaluating an application.

HOW MUCH MORE CAN ALLIGATOR ANCHORS HOLD?

Tensile Test Results (Ultimate results in pounds in 4,000 psi concrete)

Anchor Model and Diameter ALLIGATOR® Anchor Nail-in Anchor* Masonry Screw Sleeve Anchor*
A5
3/16"
(5mm)
2,316 200 600 -
AF5
3/16"
(5mm)
2,316 200 600 -
A6
1/4"
(6mm)
2,633 265 1,240 1,300
AF6
1/4"
(6mm)
2,633 265 1,240 1,300
A8
5/16"
(8mm)
3,083 - - 1,700
AF8
5/16"
(8mm)
3,083 - - 1,700
A10
3/8"
(10mm)
4,262 - - 2,500

* in 3,500 psi concrete

Industry safety standards recommend 1/4 of ultimate test load.
NOTE: A dash (-) in the chart above indicates no test result is currently available.

WHAT SIZES ARE AVAILABLE?

ALLIGATOR® anchors are available with a flange (except the A10 anchor), or without a flange (for through-the-fixture anchoring).

Flush-Mount Anchor/Drill Diameter Flanged Anchor/Drill Diameter
A5 3/16" (5mm) AF5 3/16" (5mm)
A6 1/4" (6mm) AF6 1/4" (6mm)
A8 5/16" (8mm) AF8 5/16" (8mm)
Minimum wall thickness for flanged anchors to work in hollow walls:
AF5 = 1/4"   AF6 = 3/8"   AF8 = 1/2"
Flush-Mount Anchor/Drill Diameter
A10 3/8" (10mm)
The A10 anchor works ONLY in solid walls.