Tensile Test Results
(Ultimate results in pounds in 4,000 psi concrete)
Anchor/ Diameter | ALLIGATOR Anchor | Nail-in Anchor * | Masonry Screw | Sleeve Anchor* |
|
A5 / AF5 3/16" (ø5mm) | 2,316 #10 sms | 200 | 600 | - |
|
A6 / AF6 1/4" (ø6mm) | 2,633 #14 sms | 265 | 1,240 | 1,300 |
|
A8 / AF8 5/16" (ø8mm) | 3,083 5/16" lag | - | - | 1,700 |
|
A10 3/8" (ø10mm) | 4,262 3/8" lag | - | - | 2,500 |
|
*in 3,500 psi concrete / "sms" = sheet metal screw
Industry safety standards recommend 1/4 of ultimate load.
NOTE: A dash (-) in the chart above indicates no test result is currently available.
An "F" in the anchor name (e.g., AF5) means that the anchor has a flange and should be used if you think the wall might have a cavity in it.
No "F" in the name (e.g., A5) means that the anchor has no flange and is flush-mount and suitable for push-through installations.
|